800-433-5689 U.S.A. & CANADA
817-279-9666 -FAX- 817-579-9666
GUARDIAN I STANDBY VACUUM/PRESSURE SYSTEM BELLANCA (17-31A) INSTALLATION INSTRUCTIONS . D. ROUTE VACUUM HOSE TO CLEAR OTHER COMPONENTS AND INSTALL SUPPORT CLAMPS, TY-RAPS AS REQUIRED TO PREVENT CHAFING, ETC. E. INSTALL HOSE CLAMPS ON ALL VALVES, FITTINGS, AND TIGHTEN . III. TO INSTALL ELECTRICAL COMPONENTS: A. INSTALL POWER SOURCE WIRE. REFERENCE NOTE 13/14. (POWER SOURCE WIRE HAS TERMINAL AND FUSE HOLDER INSTALLED). B. CONNECT POSITIVE WIRE TO MOTOR POSITIVE LEAD. (POSITIVE MOTOR LEAD IS MARKED IN "RED") C. SELECT AREA SHOWN, REFERENCE SHEET 5, FOR SWITCH LOCATION. NOTE 16/17. D. ROUTE WIRES THRU FIREWALL WITH EXISTING WIRE BUNDLES. E. ROUTE WIRES BEHIND INSThUMENT PANEL To SWITCH LOCATION. ROUTE AS TO PREVENT CHAFING AND INTERFERENCE WITH CONTROLS, ETC. F. INSTALL TERMINALS ON WIRES AND CONNECT TO SWITCH. G. INSTALL SWITCH AND PLACARD IN SELECTED AREA. H. CONNECT GROUND WIRE TO MOTOR GROUND LEAD; INSTALL TERMINAL AND GROUND TO THE FIREWALL. I. SECURE WIRING WITH TY-RAPS. PAGE 2 OF 3
| "GO PAGE 3" "GO PAGE 5" |