safe

800-433-5689 U.S.A. & CANADA
817-279-9666 -FAX- 817-579-9666

			GUARDIAN I STANDBY VACUUM/PRESSURE SYSTEM
					BELLANCA  (17-31A)
				 INSTALLATION INSTRUCTIONS
 		
.

	D.	ROUTE VACUUM HOSE TO CLEAR OTHER COMPONENTS AND INSTALL SUPPORT
		CLAMPS, TY-RAPS AS REQUIRED TO PREVENT CHAFING, ETC.

	E.	INSTALL HOSE CLAMPS ON ALL VALVES, FITTINGS, AND TIGHTEN
.
III. 	TO INSTALL ELECTRICAL COMPONENTS:

	A.	INSTALL POWER SOURCE WIRE.  REFERENCE NOTE 13/14. (POWER SOURCE
		WIRE HAS TERMINAL AND FUSE HOLDER INSTALLED).

	B.	CONNECT POSITIVE WIRE TO MOTOR POSITIVE LEAD.  (POSITIVE
		MOTOR LEAD IS MARKED IN "RED")

	C.	SELECT AREA SHOWN, REFERENCE SHEET 5,  FOR SWITCH LOCATION.
		NOTE 16/17.

	D.	ROUTE WIRES THRU FIREWALL WITH EXISTING WIRE BUNDLES.

	E.	ROUTE WIRES BEHIND INSThUMENT PANEL To SWITCH  LOCATION. ROUTE
		AS TO PREVENT CHAFING AND INTERFERENCE WITH CONTROLS, ETC.

	F.	INSTALL TERMINALS ON WIRES AND CONNECT TO SWITCH.

	G.	INSTALL SWITCH AND PLACARD IN SELECTED AREA.

	H.	CONNECT GROUND WIRE TO MOTOR GROUND LEAD; INSTALL TERMINAL
		AND GROUND TO THE FIREWALL.

	I.	SECURE WIRING WITH TY-RAPS.


					PAGE  2  OF  3


"GO PAGE 3"          "GO PAGE 5"